Add to Cart
HS6103 Single Phase Electricity Meter Test Bench
HS-6103 single-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.
This testing bench configurations humanized PC processing software, can provide an integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by a customer.
This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.
This series of testing bench can test all kind of single-phase energy meters, single-phase multi-function meters, single-phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.
Parameter Item | 0.03 | 0.05 | 0.1 |
Reference standard energy meter | HS-5100H 0.02 | HS-5100 0.05 | HS-5100 0.1 |
Output range | Voltage:30~300V current:1mA~120A | Voltage:30~300V current:10mA~120A(200A optional) | |
Output phase shift | 0~360°,resolution:0.01° | ||
Output frequency | 45~65Hz ,resolution:0.01Hz | ||
Waveform distortion | Both voltage and current<0.5%(relative liner load) | ||
Voltage ¤t power stability | <0.03%/120s | <0.05%/120s | <0.1%/120s |
Output capacity | Voltage:200VA (6 stations) | Voltage:400VA(24 stations)current:900VA(120A) if add meters, Max. current: 2000VA,Max. voltage: 1200VA | |
Load characteristics | Resistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF) | ||
Starting up current output | Min.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5% | ||
sampling pulse input | ≤1kHz | ||
Communication testing | RS485/232/infrared/carrier wave,support DL/T645-1997/2007,IEC1107 | ||
Number of meters to be tested | 24,48(standard),3~60 (optional) | ||
Environment condition | temperature:20℃±5℃;humidity:<85% R.H. | ||
Power supply | AC 220±10%,50/60Hz,AC120/240V(optional); Max. power consumption:1500VA(24 stations) |
integration | stations | Number of rack | dimension:L×W×H | fission | stations | Number of rack | dimension:L×W×H |
6 | 1 | 1600×750×1600 | 12 | 1 | 1600×700×1920 | ||
1600X800X1100 | 24 | 1 | 2200×700×1920 | ||||
12 | 1 | 1600×750×1920 | 48 | 2 | 2200×700×1920 | ||
24 | 1 | 2200×750×1920 | 60 | 2 | 2000×700×1920 | ||
48 | 2 | 2200×750×1920 | cabinet | 600×800×1920 |
Type | description | Range of application |
HS-6103 | Single-phase energy meter testing bench | Standard energy meter testing |
HS-6103B | Single-phase multi-function energy meter testing bench | Multi-function energy meter testing |
HS-6103C | Single-phase horizontal energy meter calibration bench | Energy meter error calibration |
HS-6103E | Single-phase energy meter test bench with ICTS | 1P3W energy meter testing |
HS-6103F | Single-phase intelligent energy meter testing bench | intelligent energy meter testing |
HS-6103G | Single-phase energy meter (round meter) testing bench | ANSI standard energy meter testing |
HS-6103M | Single-phase din-rail energy meter testing bench | din-rail energy meter testing |
HS-6103H | Single-phase high precision energy meter testing bench | high precision energy meter testing |
Function item | HS-6103 | HS-6103B | HS-6103C | HS-6103E | HS-6103F | HS-6103G | HS-6103M | HS-6103H | |
Base testing functions | Base error | ● | ● | ● | ● | ● | ● | ● | ● |
Creep testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Starting up testing | ● | ● | ● | ● | ● | ● | ● | ● | |
standard deviation | ● | ● | ● | ● | ● | ● | ● | ● | |
Constant calibration | ● | ● | ● | ● | ● | ● | ● | ● | |
Counting error | ● | ● | ● | ● | ● | ● | ● | ● | |
Influencing testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Multi-function testing | Daily timing error☆ | ● | 〇 | 〇 | ● | 〇 | |||
Period switching | ● | 〇 | ● | 〇 | |||||
Energy display error | ● | ● | |||||||
register checking | ● | ● | |||||||
GPS clock synchronization☆ | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
Communication testing☆ | ● | 〇 | 〇 | ● | 〇 | 〇 | 〇 |
For Item ☆ need special function parts
Type | HS-6103 | HS-6103B | HS-6103C | HS-6103E | HS-6103F | HS-6103G | HS-6103M | HS-6103H |
Standard energy meter | ● | ● | ● | ● | ● | ● | ● | ● |
power source | ● | ● | ● | ● | ● | ● | ● | ● |
error processing system | ● | ● | ● | ● | ● | ● | ● | ● |
multi-path pulse input | ● | 〇 | 〇 | ● | 〇 | 〇 | 〇 | |
auto searching mark | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
Double circuit current | 〇 | 〇 | ● | ● | ● | 〇 | 〇 | |
auto short circuit | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
cutting Neutral testing | 〇 | 〇 | ||||||
multi-path PT | ● | ● | ● | ● | ● | ● | ● | ● |
ICT | ● | |||||||
parallel communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
carrier communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
IR communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
power consumption testing | 〇 | 〇 | ||||||
DC and even harmonic wave | 〇 | 〇 | ||||||
standard clock tester | ● | 〇 | 〇 | ● | 〇 | |||
GPS clock synchronization | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
collective turn over & optoelectronic sampling | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
48 POSITION SINGLE-PHASE PREPAID DIGITAL KWH METER TEST BENCH
Technical Specification: 1. No. of test points: 48 meters 2. Can test both mechanical and electronic meters 3. Accuracy Class: 0.05 IEC standard 4. Multiplex voltage transformer accuracy class: 0.01 5. Rated Load Per Point: 15VA 6. Output Voltage: 220V or 240V; Adjustment range: 0-120%; Adjustment resolution: 0.01% 7. Output Current Range: 0-120A; Adjustment resolution: 0.01% 8. Phase Angle Range: 0-360deg; Adjustment resolution: 0.01 deg 9. Output wave distortion (both voltage and current): <0.5% 10. Output capacity, current: 2000VA (120A); voltage: 720 VA(48 meters) 11. Load characteristics: resistive, inductive, and capacitive (<4uF) 12. Starting current output: 5mA (min.); Accuracy of starting power: 5% 13. Test items: accuracy test, creeping test, starting test, harmonic test, repeatability test, influence test 14. Power supply: 200V-250V; 60Hz; Maximum power: 2500VA (48 meters) |