Technical Parameters:
1.Output Voltage: 220V. Output Capacity : Max.50VA
2.Output Current: 0.1A,1A,5A,20A,100A. Output capacity: Max 100VA(100A)
- Output voltage and current distortion not larger than 0.3%(if it is a linear load)
- The variation of pre-set output power within 180S will not exceed 0.02% compared with the measurement range
- Number of harmonic wave: 2-31
- Content of harmonic wave: less than 40%(compared with basewave)
- Phase of harmonic wave: 0°-359.99°
- Reading will be made directly from the standard watt-hour meter
- AC single-phase 220/240(110V also available), 50/60hz, maximum input power consumption: 500W
- Outer dimensions: 510x540x200mm
Rear:

Feature:
1.Can test 3 Meters.
2.Can communication with Meter by RS485.
3.Auto test by software.
4.Test Function:
Intrinsic Error,Creeping Test,Start Test,Constant Test,Harmonic Test,Standard deviation,
Packing Details: